You are currently accessing this Site as a guest which gives you limited access to most discussions and other features. By registering you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, register today!

If you have any problems with the registration process or your account login, please contact contact us. If you forgot your password, click here to request a new one.

Tags:

Reply
 
LinkBack Thread Tools Rate Thread Display Modes
  #1 (permalink)  
Old 03-13-2004, 04:43 AM
Registered User
 
Join Date: Aug 2003
Location: Somers CT/ Incline Village NV
Posts: 42
Thanks: 1
Thanked 12 Times in 7 Posts
ksamolyk is on a distinguished road
Hemobag Video showing Clinical Use

Global Blood Resources is proud to present this short video(2.5min) www.mybloodfirst.com/video.html for professionals with a specific interest in autologous blood conservation and management.

Please review this short video offering a new alternative to "Cell Savers" for salvaging and concentrating autologous whole blood in Cardiac, Thoracic and Vascular surgery from extracorporeal circuits. The technique is modified to use with witness patients

Thank you for your time,

Respectfully,


Global Blood Resources LLC
P.O. Box 383 Somers CT. 06071
Tel (800) - 942 - 9243
Fax (860) - 763 - 7045
www.mybloodfirst.com
www.Hemobag.com

Quote:
Originally Posted by jbwade
I am pleased to introduce Keith Samolyk. I encourage all blood utilization professionals to take a close look at the Hemobag. Feel free to contact Keith directly using the information at the end of the following text - Jan

------------------------------------------------------------
Greetings:

My name is Keith Samolyk and I am a practicing perfusionist who started a company called Global Blood Resources LLC (GBR) and Patented, developed and now have brought to market a Hemoconcentrating Reservoir called the HemobagTM that can be used with any Hemoconcentrator and Salvages Blood from any Extracorporeal Circuit quickly while still keeping the circuit primed for security.(The key is that it is concentrated autologous whole blood made available quickly).

I would like to bring you up to date as a lot has happened since we last talked. First and foremost the Hemobag has been cleared by the FDA and is now being used clinically in 12 centers in the US in just over a month. Secondly Amsect (the leading perfusion organization globally) is about to feature an article about the Hemobag and GBR in its November issue of Amsect Today to coincide with the Emerging Technology meeting that is happening next month in Cancun. I would like to share similar information with you as well with the hope that you might give it some international exposure ("what's new") about this quick and easy way to save concentrated autologous whole blood. Thirdly International Blood Plasma News also has run an article about the Hemobag in its September issue (pg. 12 under new products) that I will attached for you in a free to use PDF format to review and decide whether you have an interest in giving the Hemobag some exposure to the guests that visit your site. I am in the process of having 5 centers collect data for publication and you would also get a copy of this as soon as it becomes available. Right now everything is very strong with efficient recovery times from CPB circuits of around 10 -12 minutes from the time you start to the time you give Anesthesia back between 750-1000 mls of autologous Whole Blood with Hct's in the 55% range for reinfusion and it can be used with Witness patients. Lastly I have developed a Rollout Article that I will submit to the press in various formats for exposure to the Cardiovascular, Thoracic, Anesthesia and Perfusion communities and markets and I will attach a copy of this as well.

As you can tell I very excited about this, because it has been almost 8 years since I first started this project and it is finally becoming a reality.

Keith Samolyk CCP, LCP

Global Blood Resources LLC
P.O. Box 383 Somers , CT. 06071
Tel (800) - 942 - 9243
Fax (860) - 763 - 7045
www.mybloodfirst.com
http://www.hemobag.com/

----------------------------------------------------
Press Release

THE HEMOBAGTM, A NEW DEVICE TO SALVAGE WHOLE BLOOD

Global Blood Resources LLC (P.O. Box 383, Somers CT 06071)
has obtained FDA clearance to market its New Blood Salvaging Device
(The HemobagTM and TS3 Tubing Set). The HemobagTM salvages autologous whole blood from any extracorporeal circuit and doubles the use of existing hemoconcentrators, while keeping the security of a primed circuit at surgery’s end.

The HemobagTM is a universal reservoir that is filled in the surgical field off the arterial line at the end of cases that use an extracorporeal circuit. In just a short time the 2.0 liter HemobagTM reservoir can be reduced to its final product of richly concentrated RBC’s, platelets, clotting factors, albumin, and other plasma proteins.

For more information about this innovative and cost-effective blood salvaging device, visit www.mybloodfirst.com or call 1-800-942-9243. Learn how The HemobagTM can help save more autologous whole blood, combat hemodilution, and facilitate bloodless surgery.

Keith Samolyk CCP, LCP

Global Blood Resources LLC
P.O. Box 383 Somers , CT. 06071
Tel (800) - 942 - 9243
Fax (860) - 763 - 7045
www.mybloodfirst.com
__________________
Keith A. Samolyk CCP, LCP
Global Blood Resources LLC
P.O. Box 383 Somers CT. 06071
Tel (800) - 942 - 9243
Fax (860) - 285 - 0289
www.mybloodfirst.com
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote

Welcome!
To see more of this thread, please login or register.
Reply

  NoBlood > Resources > Tools & Products



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Device recycles patient's blood during surgery Jan B. Wade News and Hot Topics such as Hepatitis C, SARS and AIDS 4 03-26-2007 08:11 AM
Closed venous blood collection device dskee Shop Talk 6 08-02-2006 10:15 AM
Quality of red blood cells using the Dideco Electa autotransfusion device Nika Medical Articles and Abstracts 0 04-05-2005 08:46 PM
Alternative blood salvage device to cell savers ksamolyk Press Releases 0 03-21-2004 06:27 AM


All times are GMT -7. The time now is 09:56 PM.






Featured
Hospital Sponsors
Hospitals Directory

Click here to help us make a difference today. Yes, for the price of a cup of coffee, you can help NoBlood continue its mission to advance knowledge and awareness of transfusion alternatives, blood conservation, blood management, bloodless medicine and bloodless surgery.
Please help us continue to make a difference today.

Highlights
Looking for help?
Can you help?

Key Wiki Articles
Register - FAQ - Members List - Calendar - Files - Videos - Mark Forums Read - NoBlood.org RSS Feeds

Powered by vBulletin® Version 3.6.10
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.1.0
Copyright © 1996 - 2008, Bloodless Healthcare International, Inc.