You are currently accessing this Site as a guest. Please login or register by clicking Here
Click here to see who are advancing transfusion alternatives and blood management.
Click here and see who are advancing transfusion alternatives and blood management.

Go Back   NoBlood > Resources > Medical Articles and Abstracts


Welcome to NoBlood.

You are currently accessing this Site as a guest which gives you limited access to most discussions and other features. By registering you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, register today!

If you have any problems with the registration process or your account login, please contact contact us. If you forgot your password, click here to request a new one.

Tags: , , ,

Reply
 
LinkBack Thread Tools Rate Thread Display Modes
  #1 (permalink)  
Old 10-20-2006, 09:11 PM
Sharon Grant's Avatar
Registered User
 
Join Date: Dec 2003
Posts: 398
Thanks: 31
Thanked 70 Times in 34 Posts
Sharon Grant is on a distinguished road
Effects of cell saver autologous blood transfusion on blood loss and homologous blood

Eur J Cardiothorac Surg. 2006 Aug;30(2):271-7. Epub 2006 Jul 7

Effects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial.


Niranjan G, Asimakopoulos G, Karagounis A, Cockerill G, Thompson M, Chandrasekaran V.

Cardiothoracic Department, St. George's, Hospital, London, United Kingdom. drnij@hotmail.com

OBJECTIVE: Off-pump CABG is potentially associated with reduced intraoperative blood loss and homologous blood transfusion in comparison to on-pump CABG. In this randomised controlled study we investigated the effects of autologous cell saver blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing CABG on- versus off-CPB. METHODS: Eighty patients were randomised into one of four groups: (A) on-CPB with cell saver blood transfusion (CSBT), (B) on-CPB without CSBT, (C) off-pump with CSBT and (D) off-pump without CSBT. Volume of intraoperative autologous blood transfusion, postoperative mediastinal blood loss and homologous blood transfusion requirements were measured. Homologous blood was transfused when haemoglobin concentration fell below 8 g/dl postoperatively. Pre- and postoperatively prothrombin time and partial thromboplastin time were measured. RESULTS: Preoperative patient characteristics were well matched among the four groups. The amount of salvaged mediastinal blood available for autologous transfusion was significantly higher in the on-pump group (A) compared to the off-CPB group (C) (433+/-155 ml vs 271+/-144 ml, P=0.001). Volume of homologous blood transfusion was significantly higher in group B vs groups A, C and D (595+/-438 ml vs 179+/-214, 141+/-183 and 230+/-240 ml, respectively, P<0.005). The cell saver groups (A and C) received significantly less homologous blood than the groups without cell saver (160+/-197 ml vs 413+/-394 ml, respectively, P<0.005). Patients undergoing off-CPB surgery received significantly less homologous blood than those undergoing on-CPB CABG irrespective of cell saver blood transfusion (184+/-214 ml vs 382+/-397 ml, P<0.05). Postoperative blood loss was similar in the four groups (842+/-276, 1023+/-291, 869+/-286 and 903+/-315 ml in groups A to D, respectively, P>0.05). Clotting test results revealed no significant difference between the groups. There was no significant difference in postoperative morbidity between groups. CONCLUSION: Off-pump CABG is associated with significant reduction in intraoperative mediastinal blood loss and homologous transfusion requirements. Autologous transfusion of salvaged washed mediastinal blood reduced homologous transfusion significantly in the on-CPB group. Cell saver caused no significant adverse impact on coagulation parameters in on- or off-CPB CABG. Postoperative morbidity and blood loss were not affected by the use of CPB or autologous blood transfusion. We recommend the use of autologous blood transfusion in both on- and off-pump CABG surgery.

Entrez PubMed
__________________
Sharon Grant
Editorial Team
Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply

  NoBlood > Resources > Medical Articles and Abstracts



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is On
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Comparison of the effects of aprotinin and tranexamic acid on blood loss and red bloo Sharon Grant Medical Articles and Abstracts 0 10-20-2006 08:33 PM
Effects of cell saver autologous blood transfusion on blood loss and homologous blood Jan B. Wade Medical Articles and Abstracts 0 07-28-2006 09:26 AM
Comparative Effects of Red Blood Cell Transfusion and Increasing Blood Flow on Tissue Nika Medical Articles and Abstracts 0 04-05-2005 09:43 PM
Comparative Effects of Red Blood Cell Transfusion and Increasing Blood Flow on Tissue Jan B. Wade Medical Articles and Abstracts 0 03-05-2005 09:21 AM


All times are GMT -7. The time now is 05:41 PM.






Featured
Hospital Sponsors
Hospitals Directory

Click here to help us make a difference today. Yes, for the price of a cup of coffee, you can help NoBlood continue its mission to advance knowledge and awareness of transfusion alternatives, blood conservation, blood management, bloodless medicine and bloodless surgery.
Please help us continue to make a difference today.

Highlights
Looking for help?
Can you help?

Key Wiki Articles
Register - FAQ - Members List - Calendar - Files - Videos - Mark Forums Read - NoBlood.org RSS Feeds

Powered by vBulletin® Version 3.6.10
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.1.0
Copyright © 1996 - 2008, Bloodless Healthcare International, Inc.