You are currently accessing this Site as a guest. Please login or register by clicking Here
Click here to see who are advancing transfusion alternatives and blood management.
Click here and see who are advancing transfusion alternatives and blood management.

Go Back   NoBlood > Resources > Medical Articles and Abstracts


Welcome to NoBlood.

You are currently accessing this Site as a guest which gives you limited access to most discussions and other features. By registering you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, register today!

If you have any problems with the registration process or your account login, please contact contact us. If you forgot your password, click here to request a new one.

Reply
 
LinkBack Thread Tools Rate Thread Display Modes
  #1 (permalink)  
Old 12-01-2005, 12:05 PM
Registered User
 
Join Date: Jan 2003
Posts: 1,438
Thanks: 8
Thanked 121 Times in 71 Posts
Jan B. Wade is on a distinguished road
Getting the right blood to the right patient

http://www.ncbi.nlm.nih.gov/entrez/q...757&query_hl=1



Transfus Clin Biol. 2005 Nov 26; [Epub ahead of print]

Getting the right blood to the right patient: the contribution of near-miss event reporting and barrier analysis.

Kaplan HS.

College of Physicians and Surgeons, Columbia University, Harkness Pavillon 4-418, 622 West 168th Street, New York, NY 10032, USA.

Safety and reliability in blood transfusion are not static, but are dynamic non-events. Since performance deviations continually occur in complex systems, their detection and correction must be accomplished over and over again. Non-conformance must be detected early enough to allow for recovery or mitigation. Near-miss events afford early detection of possible system weaknesses and provide an early chance at correction. National event reporting systems, both voluntary and involuntary, have begun to include near-miss reporting in their classification schemes, raising awareness for their detection. MERS-TM is a voluntary safety reporting initiative in transfusion. Currently 22 hospitals submit reports anonymously to a central database which supports analysis of a hospital's own data and that of an aggregate database. The system encourages reporting of near-miss events, where the patient is protected from receiving an unsuitable or incorrect blood component due to a planned or unplanned recovery step. MERS-TM data suggest approximately 90% of events are near-misses, with 10% caught after issue but before transfusion. Near-miss reporting may increase total reports ten-fold. The ratio of near-misses to events with harm is 339:1, consistent with other industries' ratio of 300:1, which has been proposed as a measure of reporting in event reporting systems. Use of a risk matrix and an event's relation to protective barriers allow prioritization of these events. Near-misses recovered by planned barriers occur ten times more frequently then unplanned recoveries. A bedside check of the patient's identity with that on the blood component is an essential, final barrier. How the typical two person check is performed, is critical. Even properly done, this check is ineffective against sampling and testing errors. Blood testing at bedside just prior to transfusion minimizes the risk of such upstream events. However, even with simple and well designed devices, training may be a critical issue. Sample errors account for more than half of reported events. The most dangerous miscollection is a blood sample passing acceptance with no previous patient results for comparison. Bar code labels or collection of a second sample may counter this upstream vulnerability. Further upstream barriers have been proposed to counter the precariousness of urgent blood sample collection in a changing unstable situation. One, a linking device, allows safer labeling of tubes away from the bedside, the second, a forcing function, prevents omission of critical patient identification steps. Errors in the blood bank itself account for 15% of errors with a high potential severity. In one such event, a component incorrectly issued, but safely detected prior to transfusion, focused attention on multitasking's contribution to laboratory error. In sum, use of near-miss information, by enhancing barriers supporting error prevention and mitigation, increases our capacity to get the right blood to the right patient.

PMID: 16316757 [PubMed - as supplied by publisher]
__________________
Mr. Jan B. Wade
Blood Management Consultant
Enhance Outcomes - Control Cost
For Information Call - 360 296-1807
Email

Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply

  NoBlood > Resources > Medical Articles and Abstracts



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is On
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Notifying Blood Bank of bloodless patient kscalici Ask a Professional 2 03-29-2008 07:25 PM
Blood conservation in the critically ill patient Jan B. Wade Medical Articles and Abstracts 0 11-20-2005 06:00 AM
Anemia and Blood Transfusion in the Critically Ill Patient Jan B. Wade Medical Articles and Abstracts 0 04-11-2005 04:23 AM
Blood Transfusion Patient Education Form Elora Thorpe RN Shop Talk 3 01-09-2004 05:02 AM


All times are GMT -7. The time now is 09:29 PM.






! ! ! NEW ! ! !
NoBlood Mobile
NoBlood Mobile
beta

Bloodless Medicine and Surgery Hospitals
Bloodless Medicine and Surgery Hospitals

Featured
Hospital Sponsors

Click here to help us make a difference today. Yes, for the price of a cup of coffee, you can help NoBlood continue its mission to advance knowledge and awareness of transfusion alternatives, blood conservation, blood management, bloodless medicine and bloodless surgery.
Please help us continue to make a difference today.

Highlights
Looking for help?
Can you help?

Key Wiki Articles
Register - FAQ - Members List - Calendar - Files - Videos - Mark Forums Read - NoBlood.org RSS Feeds

Powered by vBulletin® Version 3.6.10
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.1.0
Copyright © 1996 - 2008, Bloodless Healthcare International, Inc.