You are currently accessing this Site as a guest. Please login or register by clicking Here
Click here to see who are advancing transfusion alternatives and blood management.
Click here and see who are advancing transfusion alternatives and blood management.

Go Back   NoBlood > Resources > Medical Articles and Abstracts


Welcome to NoBlood.

You are currently accessing this Site as a guest which gives you limited access to most discussions and other features. By registering you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, register today!

If you have any problems with the registration process or your account login, please contact contact us. If you forgot your password, click here to request a new one.

Tags: , , , ,

Reply
 
LinkBack Thread Tools Rate Thread Display Modes
  #1 (permalink)  
Old 04-15-2005, 03:39 PM
Registered User
 
Join Date: Jan 2003
Posts: 1,438
Thanks: 7
Thanked 115 Times in 67 Posts
Jan B. Wade is on a distinguished road
Influence of body core temperature on blood loss and transfusion requirements during

J Thorac Cardiovasc Surg. 2005 Apr;129(4):838-43.



Influence of body core temperature on blood loss and transfusion requirements during off-pump coronary artery bypass grafting: A comparison of 3 warming systems.

Hofer CK, Worn M, Tavakoli R, Sander L, Maloigne M, Klaghofer R, Zollinger A.

Background The aim of this prospective randomized trial was to evaluate the efficacy of 3 intraoperative warming systems (Warm-Touch, Thermamed SmartCare OP system, and Allon 2001) on maintenance of normothermia and to investigate their effects on perioperative bleeding and transfusion requirements in patients undergoing off-pump coronary artery bypass grafting. Methods With institutional approval/patient informed consent, 90 patients presenting for elective multiple off-pump coronary artery bypass grafting were randomly assigned to 1 of the 3 warming systems. Active warming was started after the induction of anesthesia. Perioperative transfusion was based on international guidelines. Body core temperature was recorded every 30 minutes during operation. Perioperative blood loss, autotransfusion, and allogenic transfusions were recorded. Analysis of variance was performed with post hoc Scheffe tests and chi 2 tests. Results Normothermia could be sufficiently maintained during operation by the Allon 2001 only. Final body core temperature was 34.7 degrees C +/- 0.9 degrees C (Warm-Touch), 35.6 degrees C +/- 0.8 degrees C (Thermamed SmartCare OP), and 36.5 degrees C +/- 0.4 degrees C (Allon 2001; P < .001, Warm-Touch vs Thermamed SmartCare OP, Warm-Touch vs Allon 2001, and Thermamed SmartCare OP vs Allon 2001). Perioperative blood loss was 2683 +/- 1049 mL (Warm-Touch), 2300 +/- 788 mL (Thermamed SmartCare OP), and 1497 +/- 497 mL (Allon 2001; P = .195, Warm-Touch vs Thermamed SmartCare OP; P < .001, Warm-Touch vs Allon 2001; P = .001, Thermamed SmartCare OP vs Allon 2001). Transfusion requirements were 1097 +/- 874 mL (Warm-Touch), 986 +/- 744 mL (Thermamed SmartCare OP), and 431 +/- 387 mL (Allon 2001; P = .838, Warm-Touch vs Thermamed SmartCare OP; P = .003, Warm-Touch vs Allon 2001; P = .013, Thermamed SmartCare OP vs Allon 2001). Free of allogenic transfusion were 15 (51.7%; Warm-Touch), 18 (60%; Thermamed SmartCare OP), and 24 (82.8%; Allon 2001) patients ( P = .037). Conclusions The goal of normothermia during off-pump coronary artery bypass grafting was best achieved by the Allon system. With this concept, overall blood loss and transfusion requirements were reduced, hence indicating improved quality of perioperative care.
http://www.ncbi.nlm.nih.gov/entrez/q..._uids=15821652
__________________
Mr. Jan B. Wade
Blood Management Consultant
Enhance Outcomes - Control Cost
For Information Call - 360 296-1807
Email

Digg this Post!Add Post to del.icio.usBookmark Post in TechnoratiFurl this Post!
Reply With Quote
Reply

  NoBlood > Resources > Medical Articles and Abstracts



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is On
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Influence of body core temperature on blood loss and transfusion requirements during Nika Medical Articles and Abstracts 0 04-17-2005 05:33 PM
Predictors of transfusion requirements for cardiac surgical procedures at a blood con Jan B. Wade Medical Articles and Abstracts 0 04-16-2005 12:05 PM
he effect of aspirin on blood loss and transfusion requirements in patients with femo Jan B. Wade Medical Articles and Abstracts 0 02-06-2004 10:54 AM
RBC in Liver Transplantation: influence/outcome, predict/requirements, reducing Jan B. Wade Medical Articles and Abstracts 0 12-24-2003 09:26 AM
Influence of Allogeneic Blood Transfusion on Clinical Outcome during Radiotherapy Jan B. Wade Medical Articles and Abstracts 0 08-08-2003 08:13 AM


All times are GMT -7. The time now is 06:15 PM.






Featured
Hospital Sponsors
Hospitals Directory

Click here to help us make a difference today. Yes, for the price of a cup of coffee, you can help NoBlood continue its mission to advance knowledge and awareness of transfusion alternatives, blood conservation, blood management, bloodless medicine and bloodless surgery.
Please help us continue to make a difference today.

Highlights
Looking for help?
Can you help?

Key Wiki Articles
Register - FAQ - Members List - Calendar - Files - Videos - Mark Forums Read - NoBlood.org RSS Feeds

Powered by vBulletin® Version 3.6.10
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
SEO by vBSEO 3.1.0
Copyright © 1996 - 2008, Bloodless Healthcare International, Inc.